12W CATV Power Supply

Rated Power: 12W
Input: 100-240V AC, 50 / 60Hz
Standby Power: ≤0.1W
Efficiency Level: DOE VI / COCV5
Protection: Short Circuit, OCP, OVP, OTP
Output: 5-36V

Switching power adapter-wall plug type
Model information YS12U-F
Power: 12W max.
Input: 100-240VAC 50/60Hz
Output Voltage: 5-36V
Output Current: 0.1-2A
Input current: 0.5A max.
Inrush Current: 90 Amps max. at 230VAC/50Hz,full load
Leakage Current: 0.25mA Max. at 264VAC input
Energy Efficiency Level VI : CoC 5 / DoE 6 / CEC VI
No Load Power Consumption : <0.15W
Protections: Short Circuit /Over Current /Over Voltage
Short Circuit Protection (SCP): Protection to Zero Voltage
Over Voltage Protection (OVP): ≤Vout*150%
Over Current Protection (OCP): 110%-180%
Working TEMP.: -20°C-50°C
Working Humidity: 5%-90% RH non-condensing
Storage TEMP.,Humidity and altitude: -40℃ ~+70°C ambient temperature and a 5% to 95% relative humidity range throughout an altitude range of -60 meters to +5000 meters AMSL.
Input Plug: US 2pin
Certificates and approvals: UL&cUL&cTUVus
EMC Regulation compliance FCC part 15, Subpart B, Class B  ANSI C63.4:2014
UL &cUL  mark according to UL60950-1 &UL1310:2011 UL1310:2011 R12.14  CAN/CSA C22.2 No.223-M91+GI1+GI2   UL60950-1 and CSA C22.2 No.60950-1-07 information Technology Equipment-Safety-Part1:General Requirements
RoHs compliance ROHS directive ”   2011/65/EU “
Surge test Phase angle: 90, 270 degrees, – Pulse Repetition rate: 60 sec. combination wave and ring wave ±6KV
MTBF: 100000 hours minimum at full load at 25℃ ambient
Burn-in The power supply shall be burn-in for 2 hours under nominal input and 100% load at ambient temperature of  25 degrees C
Life: continuously operation for  3-5 years alternative
Dimension: 65x27x38mm
Weight: 65g
Packing: 100PCS/CTN,45*28.5*31cm
Model: YS12-050200U YS12-060200U YS12-120100U YS12-150080U YS6-240050U YS6-360033U
DC Voltage: 5V 6V 12V 15V 24V 36V
Rated Current: 2A 2A 1A 0.8A 0.5A 0.33A
Rated Power: 10W 12W 12W 12W 12W 12W
Ripple & Noise(max.): 50mVp-p 60mVp-p 120mVp-p 150mVp-p 240mVp-p 360mVp-p
Voltage Tolerance: ±5% ±5% ±5% ±5% ±5% ±5%
Line Regulation: ±3% ±3% ±3% ±3% ±3% ±3%
Load Regulation: ±5% ±5% ±5% ±5% ±5% ±5%
Setup,Rise,Hold up time: 3 second max./40 MS max./5 MS max. at 100VAC input and output max. load.